Version 103 of the "Dell EMC: Isilon" PowerPack includes a security enhancement to node configuration and PowerPack node updates.
- Minimum Required Skylar One (SL1) Version: 8.14.1
Before You Install or Upgrade
Before you install the "Dell EMC: Isilon" PowerPack, ensure that you are running version 8.14.1 or later of Skylar One.
For details on upgrading Skylar One, see the relevant Skylar One Platform Release Notes.
Installation or Upgrade Process
To install version 103 of the "Dell EMC: Isilon" PowerPack, perform the following steps:
By default, when you install a new version of a PowerPack, the new version overwrites all content in that PowerPack that has already been installed on the target system. To prevent the new PowerPack version from overwriting local changes to some commonly customized fields, use the Enable Selective PowerPack Field Protection setting in the Behavior Settings page (System > Settings > Behavior).
To install this PowerPack:
-
Search for and download the PowerPack from the PowerPacks page at the ScienceLogic Support Center (Skylar One > PowerPacks).
-
In Skylar One (formerly SL1), go to the PowerPacksPowerPack Manager page (System > Manage > PowerPacks).
-
Click the menu and select Import PowerPack. The Import PowerPack modal appears.
-
Click and go to the PowerPack file from step 1.
-
Select the PowerPack file and click . The PowerPack Installer modal displays a list of the PowerPack contents.
-
Click . The PowerPack appears on the PowerPack Manager page.
Features
This release includes the following features:
- Dynamic Applications to discover, model, and monitor performance metrics and collect configuration data for Dell EMC Isilon devices
- Device classes for each type of Isilon device monitored
- Example credentials that you can use as templates to create a SOAP/XML credential for connecting to Isilon devices and an SNMP credential for device class alignment
NOTE: For discovery, you must create an SNMP credential and a SOAP/XML credential and then select both for the discovery session.
Enhancements and Issues Addressed
This release includes the following enhancements and addressed issues:
-
Addressed an issue in which node discovery reported all nodes regardless of physical node status.
-
Addressed an issue in which duplicate component devices appear, when upgraded, due to the changing of unique node IDs. Customers must manually remove existing components and then upgrade the PowerPack, or they will need to upgrade the PowerPack and then, manually remove the old components.
-
Introduced a security enhancement to the Dell EMC Isilon Node Hardware Configuration.
Known Issues
There are no known issues associated with this PowerPack.