Version 106 of the "F5 BIG-IP" PowerPack updates the PowerPack to Python 3.11 and updates the event policy description for better consumption by Skylar One (formerly SL1).
- Minimum Required Skylar One (SL1) Version: 12.3.1
Before You Install or Upgrade
Ensure that you are running version 12.3.1 or later of Skylar One before installing the "F5 BIG-IP" PowerPack.
For details on upgrading Skylar One, see the relevant Skylar One Platform Release Notes.
Installation or Upgrade Process
To install version 106 of the "F5 BIG-IP" PowerPack, perform the following steps:
To install this PowerPack:
-
Search for and download the PowerPack from the PowerPacks page at the ScienceLogic Support Center (Skylar One > PowerPacks).
-
In Skylar One (formerly SL1), go to the PowerPacks page (System > Manage > PowerPacks).
-
Click the Actions menu and choose Import PowerPack. The Import PowerPack modal appears.
-
Click and navigate to the PowerPack file from step 1.
-
Select the PowerPack file and click . The PowerPack Installer modal displays a list of the PowerPack contents.
-
Click . The PowerPack is added to the PowerPack Manager page.
Features
This release includes the following features:
- Dynamic Applications that collect configuration and performance data about F5 BIG-IP devices
- Device classes for all F5 BIG-IP devices
- Event policies that are triggered when F5 BIG-IP devices meet certain status criteria
Enhancements and Issues Addressed
The following enhancements and addressed issues are included in this release:
- Updated the PowerPack from Python version 3.6 to version 3.11.
- Updated the event policy descriptions in the PowerPack so they are more easily consumed by Skylar One.
If you upgrade the PowerPack, any content you customized in your event policy descriptions might be overwritten.
Known Issues & Workarounds
The following known issues affect version 106 of the "F5 BIG-IP" PowerPack:
-
The PowerPack contains a collection object called "ASN.1 Encoded Name" that was added on previous versions. This collection object is present in the "F5 BIG-IP LTM: Pool Configuration", "F5 BIG-IP LTM: Pool Member Configuration", and "F5 BIG-IP LTM: Node Configuration" Dynamic Applications. This collection object is not collecting data and will be disabled 48 hours after aligning the Dynamic Applications to a device.
-
All snippets display a "RequestsDependency" warning, which is caused by importing requests in python3.6 or python3.9. This warning does not affect collection.
-
Virtual servers with the same name might have only one discovered instance of duplicate named servers discovered, modeled, and present in the configuration table in the "F5 Big-IP LTM: Virtual Server Discovery" Dynamic Application. Additionally, due to a change in how Python 2 and Python 3 handle dictionaries, when upgrading from version 103 to version 104, the duplicated device that is discovered, modeled, and listed in the configuration table might change.
F5 and ScienceLogic both recommend that virtual servers have unique names.